DELTA®-VENT S
Vapor permeable 3-layer roof underlayment for all roof claddings. Tough, waterproof, and wind resistant. Provides reliable protection against wind driven rain and snow and allows moisture within the roof cavity to escape.
DELTA®-VENT S is highly vapor permeable, allowing moisture within the roof to escape through the membrane. Its high permeability makes it an ideal underlayment for non- or poorly-ventilated roofs with concrete, clay, or slate tiles. The product is completely water proof, will protect the roof from wind-driven rain and snow. The underlayment is Class A fire-rated, and fulfills the requirements for an air barrier.
DELTA®-VENT S is a super-tough, lightweight roofing underlayment. The 3-layer, high strength spun-bonded PP breather membrane is water vapor permeable, while completely waterproof and airtight. A fabric layer on the lower side protects the membrane against damage (e.g. roughly sawed sheathing). The matte gray color of DELTA®-VENT S prevents blinding glare during installation.
DELTA®-VENT S is pleasantly light in comparison to bitumen and asphalt saturated roofing felts, making the installation quick and easy. This premium quality product unrolls quickly without skewing or buckling. The large roll size minimizes laps and maximizes productivity.
| Product name | DELTA®-VENT S | |
|---|---|---|
| Color | gray | |
|
Water vapor transmission |
820 g/m²/24 h |
ASTM E96-05, Proc. A ASTM E96-05, Proc. B |
|
Permeance |
69 perms [grains/h/ft²/in Hg] 120 perms [grains/h/ft²/in Hg] |
ASTM E96-05, Proc. A ASTM E96-05, Proc. B |
| Breaking load |
MD 75.8 lb/2in CD 47.3 lb/2in |
ASTM D5035-06 |
| Elongation at break |
MD 25.8 % CD 64.4 % |
ASTM D5035-06 |
| Tear resistance |
MD 1078 g CD 1588 g |
ASTM D1922-06a |
| Trapezoid tearing strength |
MD 21.6 lb CD 14.6 lb |
ASTM D4533-04 |
| Fastener pull-through force | 132.7 N | ASTM D3462-03 |
| Water penetration resistance | 642.8 cm | CAN/CGSB-4.2 #26.3-95 |
| Water impact penetration resistance | no water passing |
AATCC 42-2000 |
| Flame Spread | 25
NFPA Class A; UBC Class I |
ASTM E84-09 |
| Smoke developed | 105
NFPA Class A; UBC Class I |
ASTM E84-09 |
| Air permeance |
< 0.02 l/(s x m²) @ 75 Pa |
ASTM E2178 |
| Temperature range | -40 °F to +176 °F
(-40 °C to +80 °C) |
|
| Mass per unit area | > 4.4 oz/yd² (150g/m²) | CSA A220.1-06 4.4.4 |
| Roll weight | approx. 24 lb (11 kg) | |
| Roll length | 164' (50 m) | |
| Roll width | 4' 11" (1.5 m) | |
| Maximum UV (sunlight) exposure |
Always cover as soon as possible. Maximum exposure 6 weeks.
|
|
| Limitations |
Avoid use of acidic silicone sealants
|